dc.contributor.author |
Kemmegne-Mbouguen, JC
|
|
dc.contributor.author |
Tchoumi, FP
|
|
dc.contributor.author |
Mouafo-Tchinda, E
|
|
dc.contributor.author |
Langmi, HW
|
|
dc.contributor.author |
Bambalaza, Sonwabo E
|
|
dc.contributor.author |
Musyoka, Nicholas M
|
|
dc.contributor.author |
Kowenje, C
|
|
dc.contributor.author |
Mokaya, R
|
|
dc.date.accessioned |
2020-11-02T10:57:59Z |
|
dc.date.available |
2020-11-02T10:57:59Z |
|
dc.date.issued |
2020-07 |
|
dc.identifier.citation |
Kemmegne-Mbouguen, J.C. (et.al.). 2020. Simultaneous quantification of acetaminophen and tryptophan using a composite graphene foam/Zr-MOF film modified electrode. New Journal of Chemistry, v44(30), pp 13108-13117. |
en_US |
dc.identifier.issn |
1369-9261 |
|
dc.identifier.uri |
https://pubs.rsc.org/en/content/articlelanding/2020/nj/d0nj02374d#!divAbstract
|
|
dc.identifier.uri |
https://doi.org/10.1039/D0NJ02374D
|
|
dc.identifier.uri |
http://hdl.handle.net/10204/11658
|
|
dc.description |
Copyright: 2020 Royal Society of Chemistry. This is the preprint version of the work. For access to the published version, kindly visit the publisher's website. |
en_US |
dc.description.abstract |
A graphene foam/zirconium-based metal–organic framework composite (GF/UiO-66) was synthesised and then employed to modify glassy carbon electrodes (GCE). These modified electrodes were successfully used for the simultaneous detection and determination of acetaminophen (AC) and tryptophan (TRYP). The combination of GF and UiO-66 endowed the electrodes with a large surface area, good biological compatibility and stability as well as high selectivity and sensitivity. The linear calibration plots for AC and TRYP were obtained over the range of 0.5–200 µM (R2 = 0.999) and 0.5–113 µM (R2 = 0.999) with detection limits of 0.07 µM and 0.06 µM, respectively. The modified electrodes were successfully applied for the determination of AC and TRYP in a pharmaceutical preparation and urine, respectively. |
en_US |
dc.language.iso |
en |
en_US |
dc.publisher |
Royal Society of Chemistry |
en_US |
dc.relation.ispartofseries |
Worklist;23853 |
|
dc.subject |
Graphene foam |
en_US |
dc.subject |
UiO-66 |
en_US |
dc.subject |
Modified electrodes |
en_US |
dc.subject |
Electroanalysis |
en_US |
dc.subject |
Acetaminophen |
en_US |
dc.subject |
Tryptophan |
en_US |
dc.title |
Simultaneous quantification of acetaminophen and tryptophan using a composite graphene foam/Zr-MOF film modified electrode |
en_US |
dc.type |
Article |
en_US |
dc.identifier.apacitation |
Kemmegne-Mbouguen, J., Tchoumi, F., Mouafo-Tchinda, E., Langmi, H., Bambalaza, S. E., Musyoka, N. M., ... Mokaya, R. (2020). Simultaneous quantification of acetaminophen and tryptophan using a composite graphene foam/Zr-MOF film modified electrode. http://hdl.handle.net/10204/11658 |
en_ZA |
dc.identifier.chicagocitation |
Kemmegne-Mbouguen, JC, FP Tchoumi, E Mouafo-Tchinda, HW Langmi, Sonwabo E Bambalaza, Nicholas M Musyoka, C Kowenje, and R Mokaya "Simultaneous quantification of acetaminophen and tryptophan using a composite graphene foam/Zr-MOF film modified electrode." (2020) http://hdl.handle.net/10204/11658 |
en_ZA |
dc.identifier.vancouvercitation |
Kemmegne-Mbouguen J, Tchoumi F, Mouafo-Tchinda E, Langmi H, Bambalaza SE, Musyoka NM, et al. Simultaneous quantification of acetaminophen and tryptophan using a composite graphene foam/Zr-MOF film modified electrode. 2020; http://hdl.handle.net/10204/11658. |
en_ZA |
dc.identifier.ris |
TY - Article
AU - Kemmegne-Mbouguen, JC
AU - Tchoumi, FP
AU - Mouafo-Tchinda, E
AU - Langmi, HW
AU - Bambalaza, Sonwabo E
AU - Musyoka, Nicholas M
AU - Kowenje, C
AU - Mokaya, R
AB - A graphene foam/zirconium-based metal–organic framework composite (GF/UiO-66) was synthesised and then employed to modify glassy carbon electrodes (GCE). These modified electrodes were successfully used for the simultaneous detection and determination of acetaminophen (AC) and tryptophan (TRYP). The combination of GF and UiO-66 endowed the electrodes with a large surface area, good biological compatibility and stability as well as high selectivity and sensitivity. The linear calibration plots for AC and TRYP were obtained over the range of 0.5–200 µM (R2 = 0.999) and 0.5–113 µM (R2 = 0.999) with detection limits of 0.07 µM and 0.06 µM, respectively. The modified electrodes were successfully applied for the determination of AC and TRYP in a pharmaceutical preparation and urine, respectively.
DA - 2020-07
DB - ResearchSpace
DP - CSIR
KW - Graphene foam
KW - UiO-66
KW - Modified electrodes
KW - Electroanalysis
KW - Acetaminophen
KW - Tryptophan
LK - https://researchspace.csir.co.za
PY - 2020
SM - 1369-9261
T1 - Simultaneous quantification of acetaminophen and tryptophan using a composite graphene foam/Zr-MOF film modified electrode
TI - Simultaneous quantification of acetaminophen and tryptophan using a composite graphene foam/Zr-MOF film modified electrode
UR - http://hdl.handle.net/10204/11658
ER -
|
en_ZA |