dc.contributor.author |
Smith, S
|
|
dc.contributor.author |
Sewart, R
|
|
dc.contributor.author |
Land, K
|
|
dc.contributor.author |
Roux, P
|
|
dc.contributor.author |
Gärtner, C
|
|
dc.contributor.author |
Becker, H
|
|
dc.date.accessioned |
2016-07-11T10:46:54Z |
|
dc.date.available |
2016-07-11T10:46:54Z |
|
dc.date.issued |
2016-02 |
|
dc.identifier.citation |
Smith, S. Sewart, R. Land, K. Roux, P. Gärtner, C. and Becker, H. 2016. Blister pouches for effective reagent storage and release for low-cost point-of-care diagnostic applications. In: SPIE proceedings 9705, Microfluidics, BioMEMS, and Medical Microsystems XIV, 97050F, San Francisco, California, United States, 13 February 2016 |
en_US |
dc.identifier.uri |
http://spie.org/Publications/Proceedings/Paper/10.1117/12.2217963
|
|
dc.identifier.uri |
http://hdl.handle.net/10204/8619
|
|
dc.description |
SPIE proceedings 9705, Microfluidics, BioMEMS, and Medical Microsystems XIV, 97050F, San Francisco, California, United States, 13 February 2016 |
en_US |
dc.description.abstract |
Lab-on-a-chip devices are often applied to point-of-care diagnostic solutions as they are low-cost, compact, disposable, and require only small sample volumes. For such devices, various reagents are required for sample preparation and analysis and, for an integrated solution to be realized, on-chip reagent storage and automated introduction are required. This work describes the implementation and characterization of effective liquid reagent storage and release mechanisms utilizing blister pouches applied to various point-of-care diagnostic device applications. The manufacturing aspects as well as performance parameters are evaluated. |
en_US |
dc.language.iso |
en |
en_US |
dc.publisher |
SPIE |
en_US |
dc.relation.ispartofseries |
Workflow;16794 |
|
dc.subject |
Lab-on-a-chip |
en_US |
dc.subject |
Point-of-care diagnostics |
en_US |
dc.subject |
Microfluidics |
en_US |
dc.subject |
Reagent storage |
en_US |
dc.subject |
Blister pouches |
en_US |
dc.title |
Blister pouches for effective reagent storage and release for low-cost point-of-care diagnostic applications |
en_US |
dc.type |
Conference Presentation |
en_US |
dc.identifier.apacitation |
Smith, S., Sewart, R., Land, K., Roux, P., Gärtner, C., & Becker, H. (2016). Blister pouches for effective reagent storage and release for low-cost point-of-care diagnostic applications. SPIE. http://hdl.handle.net/10204/8619 |
en_ZA |
dc.identifier.chicagocitation |
Smith, S, R Sewart, K Land, P Roux, C Gärtner, and H Becker. "Blister pouches for effective reagent storage and release for low-cost point-of-care diagnostic applications." (2016): http://hdl.handle.net/10204/8619 |
en_ZA |
dc.identifier.vancouvercitation |
Smith S, Sewart R, Land K, Roux P, Gärtner C, Becker H, Blister pouches for effective reagent storage and release for low-cost point-of-care diagnostic applications; SPIE; 2016. http://hdl.handle.net/10204/8619 . |
en_ZA |
dc.identifier.ris |
TY - Conference Presentation
AU - Smith, S
AU - Sewart, R
AU - Land, K
AU - Roux, P
AU - Gärtner, C
AU - Becker, H
AB - Lab-on-a-chip devices are often applied to point-of-care diagnostic solutions as they are low-cost, compact, disposable, and require only small sample volumes. For such devices, various reagents are required for sample preparation and analysis and, for an integrated solution to be realized, on-chip reagent storage and automated introduction are required. This work describes the implementation and characterization of effective liquid reagent storage and release mechanisms utilizing blister pouches applied to various point-of-care diagnostic device applications. The manufacturing aspects as well as performance parameters are evaluated.
DA - 2016-02
DB - ResearchSpace
DP - CSIR
KW - Lab-on-a-chip
KW - Point-of-care diagnostics
KW - Microfluidics
KW - Reagent storage
KW - Blister pouches
LK - https://researchspace.csir.co.za
PY - 2016
T1 - Blister pouches for effective reagent storage and release for low-cost point-of-care diagnostic applications
TI - Blister pouches for effective reagent storage and release for low-cost point-of-care diagnostic applications
UR - http://hdl.handle.net/10204/8619
ER -
|
en_ZA |