dc.contributor.author |
Jafta, CJ
|
|
dc.contributor.author |
Roos, WD
|
|
dc.contributor.author |
Terblans, JJ
|
|
dc.date.accessioned |
2013-09-30T08:05:40Z |
|
dc.date.available |
2013-09-30T08:05:40Z |
|
dc.date.issued |
2013-03 |
|
dc.identifier.citation |
Jafta, C.J, Roos, W.D and Terblans, J.J. 2013. Modification to an Auger Electron Spectroscopy system for measuring segregation in a bi-crystal. Journal of Instrumentation, vol. 8, pp 1-6 |
en_US |
dc.identifier.issn |
1748-0221 |
|
dc.identifier.uri |
http://hdl.handle.net/10204/6970
|
|
dc.description |
Copyright: 2013 IOP Publishing. This is an ABSTRACT ONLY. The definition version is published in Journal of Instrumentation, vol. 8, pp 1-6 |
en_US |
dc.description.abstract |
It is reported that different crystal surface orientations yield different segregation fluxes. Although there were a few attempts to confirm these predictions experimentally, it is very difficult to compare data without making a few assumptions. Parameters like temperature measurement, crystal history and spectrometer variables are all adding to the complexity of directly comparing the segregation behaviour from one crystal to another. This investigation makes use of a Cu bi-crystal, modifications to the scanning control unit of the AES electron beam to eliminate the difference in experimental parameters and specialized written software to automate the data acquisition process. This makes direct comparison of segregation parameters on two different orientations possible. The paper describes the electron beam modifications, experimental setup and procedures, as well as the software developed to control the electron beam and automate data acquisition. |
en_US |
dc.language.iso |
en |
en_US |
dc.publisher |
IOP Publishing |
en_US |
dc.relation.ispartofseries |
Workflow;11478 |
|
dc.subject |
Auger Electron Spectroscopy |
en_US |
dc.subject |
Electron beam modifications |
en_US |
dc.subject |
Data distribution |
en_US |
dc.subject |
Archiving |
en_US |
dc.subject |
Detector design |
en_US |
dc.subject |
Construction technologies |
en_US |
dc.title |
Modification to an Auger Electron Spectroscopy system for measuring segregation in a bi-crystal |
en_US |
dc.type |
Article |
en_US |
dc.identifier.apacitation |
Jafta, C., Roos, W., & Terblans, J. (2013). Modification to an Auger Electron Spectroscopy system for measuring segregation in a bi-crystal. http://hdl.handle.net/10204/6970 |
en_ZA |
dc.identifier.chicagocitation |
Jafta, CJ, WD Roos, and JJ Terblans "Modification to an Auger Electron Spectroscopy system for measuring segregation in a bi-crystal." (2013) http://hdl.handle.net/10204/6970 |
en_ZA |
dc.identifier.vancouvercitation |
Jafta C, Roos W, Terblans J. Modification to an Auger Electron Spectroscopy system for measuring segregation in a bi-crystal. 2013; http://hdl.handle.net/10204/6970. |
en_ZA |
dc.identifier.ris |
TY - Article
AU - Jafta, CJ
AU - Roos, WD
AU - Terblans, JJ
AB - It is reported that different crystal surface orientations yield different segregation fluxes. Although there were a few attempts to confirm these predictions experimentally, it is very difficult to compare data without making a few assumptions. Parameters like temperature measurement, crystal history and spectrometer variables are all adding to the complexity of directly comparing the segregation behaviour from one crystal to another. This investigation makes use of a Cu bi-crystal, modifications to the scanning control unit of the AES electron beam to eliminate the difference in experimental parameters and specialized written software to automate the data acquisition process. This makes direct comparison of segregation parameters on two different orientations possible. The paper describes the electron beam modifications, experimental setup and procedures, as well as the software developed to control the electron beam and automate data acquisition.
DA - 2013-03
DB - ResearchSpace
DP - CSIR
KW - Auger Electron Spectroscopy
KW - Electron beam modifications
KW - Data distribution
KW - Archiving
KW - Detector design
KW - Construction technologies
LK - https://researchspace.csir.co.za
PY - 2013
SM - 1748-0221
T1 - Modification to an Auger Electron Spectroscopy system for measuring segregation in a bi-crystal
TI - Modification to an Auger Electron Spectroscopy system for measuring segregation in a bi-crystal
UR - http://hdl.handle.net/10204/6970
ER -
|
en_ZA |