ResearchSpace

Laboratory panel and radiometer calibration

Show simple item record

dc.contributor.author Deadman, AJ
dc.contributor.author Behnert, ID
dc.contributor.author Fox, NP
dc.contributor.author Griffith, D
dc.date.accessioned 2012-01-05T06:59:29Z
dc.date.available 2012-01-05T06:59:29Z
dc.date.issued 2011-07
dc.identifier.citation Deadman, AJ, Behnert, ID, Fox, NP and Griffith, D. 2011. Laboratory panel and radiometer calibration. 2011 IEEE Geoscience and Remote Sensing Symposium, Vancouver, BC, Canada, 24-29 July 2011 en_US
dc.identifier.uri http://hdl.handle.net/10204/5431
dc.description 2011 IEEE Geoscience and Remote Sensing Symposium, Vancouver, BC, Canada, 24-29 July 2011 en_US
dc.description.abstract This paper presents the results of the laboratory and field based reflectance panel and radiometer comparisons that took place as part of the CEOS 2010 Key comparison of “techniques and instruments used for the vicarious calibration of Land surface imaging through a ground reference standard test site”. The results of the comparisons are presented which shows that the different ways in which reflectance panels are calibrated can give different results for the reflectance attributed to a test site and that changing illumination and environmental conditions can effect the measured target reflectance. en_US
dc.language.iso en en_US
dc.publisher IEEE IGARSS 2011 en_US
dc.relation.ispartofseries Workflow request;7810
dc.subject Earth observation en_US
dc.subject Field spectroscopy en_US
dc.subject Reflectance factor en_US
dc.subject Vicarious calibration en_US
dc.subject Geosciences en_US
dc.subject Remote sensing en_US
dc.subject IEEE IGARSS 2011 en_US
dc.title Laboratory panel and radiometer calibration en_US
dc.type Conference Presentation en_US
dc.identifier.apacitation Deadman, A., Behnert, I., Fox, N., & Griffith, D. (2011). Laboratory panel and radiometer calibration. IEEE IGARSS 2011. http://hdl.handle.net/10204/5431 en_ZA
dc.identifier.chicagocitation Deadman, AJ, ID Behnert, NP Fox, and D Griffith. "Laboratory panel and radiometer calibration." (2011): http://hdl.handle.net/10204/5431 en_ZA
dc.identifier.vancouvercitation Deadman A, Behnert I, Fox N, Griffith D, Laboratory panel and radiometer calibration; IEEE IGARSS 2011; 2011. http://hdl.handle.net/10204/5431 . en_ZA
dc.identifier.ris TY - Conference Presentation AU - Deadman, AJ AU - Behnert, ID AU - Fox, NP AU - Griffith, D AB - This paper presents the results of the laboratory and field based reflectance panel and radiometer comparisons that took place as part of the CEOS 2010 Key comparison of “techniques and instruments used for the vicarious calibration of Land surface imaging through a ground reference standard test site”. The results of the comparisons are presented which shows that the different ways in which reflectance panels are calibrated can give different results for the reflectance attributed to a test site and that changing illumination and environmental conditions can effect the measured target reflectance. DA - 2011-07 DB - ResearchSpace DP - CSIR KW - Earth observation KW - Field spectroscopy KW - Reflectance factor KW - Vicarious calibration KW - Geosciences KW - Remote sensing KW - IEEE IGARSS 2011 LK - https://researchspace.csir.co.za PY - 2011 T1 - Laboratory panel and radiometer calibration TI - Laboratory panel and radiometer calibration UR - http://hdl.handle.net/10204/5431 ER - en_ZA


Files in this item

This item appears in the following Collection(s)

Show simple item record