ResearchSpace

Influence of variation in eumelanin content on absorbance spectra of liquid skin-like phantoms

Show simple item record

dc.contributor.author Smit, Jacoba E
dc.contributor.author Grobler, AF
dc.contributor.author Sparrow, RW
dc.date.accessioned 2011-01-11T12:52:12Z
dc.date.available 2011-01-11T12:52:12Z
dc.date.issued 2011-01
dc.identifier.citation Smit, JE, Grobler, AF and Sparrow, RW. 2010. Influence of variation in eumelanin content on absorbance spectra of liquid skin-like phantoms. Photochemistry and Photobiology, Vol. 87(1), pp 64-71 en
dc.identifier.issn 0031-8655
dc.identifier.uri http://www.ncbi.nlm.nih.gov/pubmed/21073475
dc.identifier.uri http://hdl.handle.net/10204/4755
dc.description Copyright: 2011 Wiley Blackwell. This is the pre print version of the work. The definitive version is published in Photochemistry and Photobiology, Vol. 87(1), pp 64-71 en
dc.description.abstract The attenuation behaviour of two different types of skin-like phantoms representing the range of Skin Types I to VI were investigated and compared to real human skin. Intralipid and PheroidTM artificial lipid membrane vesicles respectively were added to synthetic eumelanin concentrations ranging from 0.0044 to 0.13 mg/mL to produce skin-like phantoms. Spectrophotometric absorbance and transmittance measurements were performed. Results predicted some of the non-monotonic trends observed in real human skin, albeit shifted more towards the visible wavelength range. There exist however an underlying difference in interaction between the melanin and the PheroidTM and Intralipid skin-like phantoms en
dc.language.iso en en
dc.publisher Wiley Blackwell en
dc.relation.ispartofseries Journal Article en
dc.subject Phantoms en
dc.subject Skin-like phantoms en
dc.subject Eumelanin en
dc.subject Spectrophotometric absorbance en
dc.title Influence of variation in eumelanin content on absorbance spectra of liquid skin-like phantoms en
dc.type Article en
dc.identifier.apacitation Smit, J. E., Grobler, A., & Sparrow, R. (2011). Influence of variation in eumelanin content on absorbance spectra of liquid skin-like phantoms. http://hdl.handle.net/10204/4755 en_ZA
dc.identifier.chicagocitation Smit, Jacoba E, AF Grobler, and RW Sparrow "Influence of variation in eumelanin content on absorbance spectra of liquid skin-like phantoms." (2011) http://hdl.handle.net/10204/4755 en_ZA
dc.identifier.vancouvercitation Smit JE, Grobler A, Sparrow R. Influence of variation in eumelanin content on absorbance spectra of liquid skin-like phantoms. 2011; http://hdl.handle.net/10204/4755. en_ZA
dc.identifier.ris TY - Article AU - Smit, Jacoba E AU - Grobler, AF AU - Sparrow, RW AB - The attenuation behaviour of two different types of skin-like phantoms representing the range of Skin Types I to VI were investigated and compared to real human skin. Intralipid and PheroidTM artificial lipid membrane vesicles respectively were added to synthetic eumelanin concentrations ranging from 0.0044 to 0.13 mg/mL to produce skin-like phantoms. Spectrophotometric absorbance and transmittance measurements were performed. Results predicted some of the non-monotonic trends observed in real human skin, albeit shifted more towards the visible wavelength range. There exist however an underlying difference in interaction between the melanin and the PheroidTM and Intralipid skin-like phantoms DA - 2011-01 DB - ResearchSpace DP - CSIR KW - Phantoms KW - Skin-like phantoms KW - Eumelanin KW - Spectrophotometric absorbance LK - https://researchspace.csir.co.za PY - 2011 SM - 0031-8655 T1 - Influence of variation in eumelanin content on absorbance spectra of liquid skin-like phantoms TI - Influence of variation in eumelanin content on absorbance spectra of liquid skin-like phantoms UR - http://hdl.handle.net/10204/4755 ER - en_ZA


Files in this item

This item appears in the following Collection(s)

Show simple item record