Interferometric method to determine the Kerr constant of perspex and ZnSe

Show simple item record

dc.contributor.author Govender, P
dc.contributor.author Couling, VW
dc.date.accessioned 2010-12-20T09:58:10Z
dc.date.available 2010-12-20T09:58:10Z
dc.date.issued 2010-09
dc.identifier.citation Govender, P and Couling, VW. 2010. Interferometric method to determine the Kerr constant of perspex and ZnSe. 55th Annual Conference of the South African Institute of Physics (SAIP), CSIR International Convention Centre, Pretoria, 27 September-1 October 2010, pp 1 en
dc.identifier.uri http://hdl.handle.net/10204/4681
dc.description 55th Annual Conference of the South African Institute of Physics (SAIP), CSIR International Convention Centre, Pretoria, 27 September-1 October 2010 en
dc.description.abstract An adapted Michelson interferometric technique was used to measure strain induced birefringence in perspex. The birefringence was then used to determine the Kerr constant in perspex. The result obtained is compared to a colarimetric result and is shown to be a more sophisticated and reliable method. en
dc.language.iso en en
dc.publisher SAIP 2010 en
dc.relation.ispartofseries Conference Paper en
dc.subject Michelson interferometric technique en
dc.subject Birefringence en
dc.subject Perspex en
dc.subject Kerr constant en
dc.subject Physics en
dc.subject SAIP 2010 en
dc.title Interferometric method to determine the Kerr constant of perspex and ZnSe en
dc.type Conference Presentation en
dc.identifier.apacitation Govender, P., & Couling, V. (2010). Interferometric method to determine the Kerr constant of perspex and ZnSe. SAIP 2010. http://hdl.handle.net/10204/4681 en_ZA
dc.identifier.chicagocitation Govender, P, and VW Couling. "Interferometric method to determine the Kerr constant of perspex and ZnSe." (2010): http://hdl.handle.net/10204/4681 en_ZA
dc.identifier.vancouvercitation Govender P, Couling V, Interferometric method to determine the Kerr constant of perspex and ZnSe; SAIP 2010; 2010. http://hdl.handle.net/10204/4681 . en_ZA
dc.identifier.ris TY - Conference Presentation AU - Govender, P AU - Couling, VW AB - An adapted Michelson interferometric technique was used to measure strain induced birefringence in perspex. The birefringence was then used to determine the Kerr constant in perspex. The result obtained is compared to a colarimetric result and is shown to be a more sophisticated and reliable method. DA - 2010-09 DB - ResearchSpace DP - CSIR KW - Michelson interferometric technique KW - Birefringence KW - Perspex KW - Kerr constant KW - Physics KW - SAIP 2010 LK - https://researchspace.csir.co.za PY - 2010 T1 - Interferometric method to determine the Kerr constant of perspex and ZnSe TI - Interferometric method to determine the Kerr constant of perspex and ZnSe UR - http://hdl.handle.net/10204/4681 ER - en_ZA


Files in this item

This item appears in the following Collection(s)

Show simple item record