ResearchSpace

Performance of a generic non-axisymmetric end wall in a single stage, rotating turbine at on and off-design conditions

Show simple item record

dc.contributor.author Snedden, Glen C
dc.contributor.author Dunn, Dwain I
dc.contributor.author Ingram, G
dc.contributor.author Gregory-Smith, D
dc.date.accessioned 2010-12-10T10:18:19Z
dc.date.available 2010-12-10T10:18:19Z
dc.date.issued 2010-06
dc.identifier.citation Snedden, GC, Dunn, D, Ingram, G and Gregory-Smith, D. 2010. Performance of a generic non-axisymmetric end wall in a single stage, rotating turbine at on and off-design conditions. ASME Turbo Expo 2010: Power for Land, Sea and Air. Glasgow, 14-18 June 2010, pp 12 en
dc.identifier.uri http://hdl.handle.net/10204/4651
dc.description ASME Turbo Expo 2010: Power for Land, Sea and Air. Glasgow, 14-18 June 2010 en
dc.description.abstract The application of non-axisymmetric end walls in turbine stages has gained wide spread acceptance as a means to improve the performance of turbines in both power generation and aero-derivative applications. Non-axisymmetric end walls are aimed at the control of secondary flows and to a large extent have been developed through the use of computational fluid dynamics and detailed measurements in linear and annular cascades and proven in full scale engine tests. Little or no literature is available describing their performance at conditions other than design. This study utilises 5-hole probe measurements in a low speed, model turbine in conjunction with computational fluid dynamics to gain a more detailed understanding of the influence of a generic end wall design on the structure of secondary flows at both on and off-design flow conditions. Results indicate a 0.4% improvement in rotor efficiency at design but this was reduced at off design and at higher loading the rotor efficiency was reduced by 0.5%. Stage efficiencies were improved for all conditions but with a declining trend as load was increased. Experimental and CFD results are examined to investigate these findings further. en
dc.language.iso en en
dc.publisher 2010 by ASME en
dc.relation.ispartofseries Conference Paper en
dc.subject Non-axisymmetric end wal en
dc.subject Generic non-axisymmetric en
dc.subject Rotating turbines en
dc.subject ASME Turbo Expo 2010 en
dc.title Performance of a generic non-axisymmetric end wall in a single stage, rotating turbine at on and off-design conditions en
dc.type Conference Presentation en
dc.identifier.apacitation Snedden, G. C., Dunn, D. I., Ingram, G., & Gregory-Smith, D. (2010). Performance of a generic non-axisymmetric end wall in a single stage, rotating turbine at on and off-design conditions. 2010 by ASME. http://hdl.handle.net/10204/4651 en_ZA
dc.identifier.chicagocitation Snedden, Glen C, Dwain I Dunn, G Ingram, and D Gregory-Smith. "Performance of a generic non-axisymmetric end wall in a single stage, rotating turbine at on and off-design conditions." (2010): http://hdl.handle.net/10204/4651 en_ZA
dc.identifier.vancouvercitation Snedden GC, Dunn DI, Ingram G, Gregory-Smith D, Performance of a generic non-axisymmetric end wall in a single stage, rotating turbine at on and off-design conditions; 2010 by ASME; 2010. http://hdl.handle.net/10204/4651 . en_ZA
dc.identifier.ris TY - Conference Presentation AU - Snedden, Glen C AU - Dunn, Dwain I AU - Ingram, G AU - Gregory-Smith, D AB - The application of non-axisymmetric end walls in turbine stages has gained wide spread acceptance as a means to improve the performance of turbines in both power generation and aero-derivative applications. Non-axisymmetric end walls are aimed at the control of secondary flows and to a large extent have been developed through the use of computational fluid dynamics and detailed measurements in linear and annular cascades and proven in full scale engine tests. Little or no literature is available describing their performance at conditions other than design. This study utilises 5-hole probe measurements in a low speed, model turbine in conjunction with computational fluid dynamics to gain a more detailed understanding of the influence of a generic end wall design on the structure of secondary flows at both on and off-design flow conditions. Results indicate a 0.4% improvement in rotor efficiency at design but this was reduced at off design and at higher loading the rotor efficiency was reduced by 0.5%. Stage efficiencies were improved for all conditions but with a declining trend as load was increased. Experimental and CFD results are examined to investigate these findings further. DA - 2010-06 DB - ResearchSpace DP - CSIR KW - Non-axisymmetric end wal KW - Generic non-axisymmetric KW - Rotating turbines KW - ASME Turbo Expo 2010 LK - https://researchspace.csir.co.za PY - 2010 T1 - Performance of a generic non-axisymmetric end wall in a single stage, rotating turbine at on and off-design conditions TI - Performance of a generic non-axisymmetric end wall in a single stage, rotating turbine at on and off-design conditions UR - http://hdl.handle.net/10204/4651 ER - en_ZA


Files in this item

This item appears in the following Collection(s)

Show simple item record