dc.contributor.author |
Schneider, F
|
|
dc.contributor.author |
Draheim, J
|
|
dc.contributor.author |
Brunne, J
|
|
dc.contributor.author |
Waibel, P
|
|
dc.contributor.author |
Wallrabe, U
|
|
dc.date.accessioned |
2010-10-25T14:44:07Z |
|
dc.date.available |
2010-10-25T14:44:07Z |
|
dc.date.issued |
2010-03 |
|
dc.identifier.citation |
Schneider, F, Draheim, J, Brunne, J et al. 2010. Characterisation of adaptive fluidic silicone-membrane lenses. South African Institute of Electrical Engineers, Vol. 101(1), pp 21-25 |
en |
dc.identifier.uri |
http://www.saiee.org.za/publications/2010/March/101_1_4.pdf
|
|
dc.identifier.uri |
http://hdl.handle.net/10204/4506
|
|
dc.description |
Copyright: 2010 South African Institute of Electrical Engineers |
en |
dc.description.abstract |
The authors compare the performance and optical quality of two types of adaptive fluidic silicone-membrane lenses. The membranes feature either a homogeneous thickness, or they are shaped resulting in an inhomogeneous cross-section. The lens systems incorporate a piezoelectric actuator which is operated in a regime of ±40 V. The shaped membrane lenses show lower wave front errors than the planar ones, down to 24 nm. The pumping actuator indicates a maximum pump volume of 1159 nl at an inner piezo radius of 2.75 mm for the smallest supporting ring configuration. The full system with a planar membrane achieves a larger refractive power ranging from +19 to -14 dpt. It also shows a shorter full scale response time (tplanar = 23.9 ms) compared to the shaped membrane (tshaped = 35.4 ms). |
en |
dc.language.iso |
en |
en |
dc.publisher |
South African Institution of Electrical Engineers |
en |
dc.relation.ispartofseries |
Journal of Power Sources |
en |
dc.subject |
Adaptive optics |
en |
dc.subject |
Piezoelectric actuator |
en |
dc.subject |
Silicone |
en |
dc.subject |
Electrical engineering |
en |
dc.title |
Characterisation of adaptive fluidic silicone-membrane lenses |
en |
dc.type |
Article |
en |
dc.identifier.apacitation |
Schneider, F., Draheim, J., Brunne, J., Waibel, P., & Wallrabe, U. (2010). Characterisation of adaptive fluidic silicone-membrane lenses. http://hdl.handle.net/10204/4506 |
en_ZA |
dc.identifier.chicagocitation |
Schneider, F, J Draheim, J Brunne, P Waibel, and U Wallrabe "Characterisation of adaptive fluidic silicone-membrane lenses." (2010) http://hdl.handle.net/10204/4506 |
en_ZA |
dc.identifier.vancouvercitation |
Schneider F, Draheim J, Brunne J, Waibel P, Wallrabe U. Characterisation of adaptive fluidic silicone-membrane lenses. 2010; http://hdl.handle.net/10204/4506. |
en_ZA |
dc.identifier.ris |
TY - Article
AU - Schneider, F
AU - Draheim, J
AU - Brunne, J
AU - Waibel, P
AU - Wallrabe, U
AB - The authors compare the performance and optical quality of two types of adaptive fluidic silicone-membrane lenses. The membranes feature either a homogeneous thickness, or they are shaped resulting in an inhomogeneous cross-section. The lens systems incorporate a piezoelectric actuator which is operated in a regime of ±40 V. The shaped membrane lenses show lower wave front errors than the planar ones, down to 24 nm. The pumping actuator indicates a maximum pump volume of 1159 nl at an inner piezo radius of 2.75 mm for the smallest supporting ring configuration. The full system with a planar membrane achieves a larger refractive power ranging from +19 to -14 dpt. It also shows a shorter full scale response time (tplanar = 23.9 ms) compared to the shaped membrane (tshaped = 35.4 ms).
DA - 2010-03
DB - ResearchSpace
DP - CSIR
KW - Adaptive optics
KW - Piezoelectric actuator
KW - Silicone
KW - Electrical engineering
LK - https://researchspace.csir.co.za
PY - 2010
T1 - Characterisation of adaptive fluidic silicone-membrane lenses
TI - Characterisation of adaptive fluidic silicone-membrane lenses
UR - http://hdl.handle.net/10204/4506
ER -
|
en_ZA |