dc.contributor.author |
Hecker, GFK
|
|
dc.date.accessioned |
2008-01-18T12:29:22Z |
|
dc.date.available |
2008-01-18T12:29:22Z |
|
dc.date.issued |
2004-01 |
|
dc.identifier.citation |
Hecker, GFK. 2004. Develop discard criteria for non-spin wire ropes. Safety in Mines Research Advisory Committee, GAP 803, January, 2004, pp 1-33 |
en |
dc.identifier.uri |
http://hdl.handle.net/10204/1854
|
|
dc.description.abstract |
The initial project objective was to correlate the level of internal broken wire indications, obtained using a magnetic rope test instrument, with rope strength loss and then to propose a given indication level at which non-spin ropes are to be discarded. No experimental data became available during the course of the project and, therefore, relatively conservative discard were recommended, based on current practice and on discussions with rope inspectors and other parties concerned with rope safety. Two appendices to the report present recommended changes to the discard criteria and other changes to the code of practice for rope condition assessment (SABS0293) respectively. Where appropriate, background information is presented to facilitate a decision on how to implement these changes. A third appendix presents responses obtained when the draft version of this report was circulated. |
en |
dc.language.iso |
en |
en |
dc.subject |
SIMRAC |
en |
dc.subject |
GAP 803 |
en |
dc.subject |
Discard criteria |
en |
dc.subject |
Develop |
en |
dc.subject |
Non-spin wire ropes |
en |
dc.subject |
Broken wire indications |
en |
dc.title |
Develop discard criteria for non-spin wire ropes |
en |
dc.type |
Conference Presentation |
en |
dc.identifier.apacitation |
Hecker, G. (2004). Develop discard criteria for non-spin wire ropes. http://hdl.handle.net/10204/1854 |
en_ZA |
dc.identifier.chicagocitation |
Hecker, GFK. "Develop discard criteria for non-spin wire ropes." (2004): http://hdl.handle.net/10204/1854 |
en_ZA |
dc.identifier.vancouvercitation |
Hecker G, Develop discard criteria for non-spin wire ropes; 2004. http://hdl.handle.net/10204/1854 . |
en_ZA |
dc.identifier.ris |
TY - Conference Presentation
AU - Hecker, GFK
AB - The initial project objective was to correlate the level of internal broken wire indications, obtained using a magnetic rope test instrument, with rope strength loss and then to propose a given indication level at which non-spin ropes are to be discarded. No experimental data became available during the course of the project and, therefore, relatively conservative discard were recommended, based on current practice and on discussions with rope inspectors and other parties concerned with rope safety. Two appendices to the report present recommended changes to the discard criteria and other changes to the code of practice for rope condition assessment (SABS0293) respectively. Where appropriate, background information is presented to facilitate a decision on how to implement these changes. A third appendix presents responses obtained when the draft version of this report was circulated.
DA - 2004-01
DB - ResearchSpace
DP - CSIR
KW - SIMRAC
KW - GAP 803
KW - Discard criteria
KW - Develop
KW - Non-spin wire ropes
KW - Broken wire indications
LK - https://researchspace.csir.co.za
PY - 2004
T1 - Develop discard criteria for non-spin wire ropes
TI - Develop discard criteria for non-spin wire ropes
UR - http://hdl.handle.net/10204/1854
ER -
|
en_ZA |