ResearchSpace

International comparison of 50/60 Hz power (1996-1999)

Show simple item record

dc.contributor.author Oldham, N en_US
dc.contributor.author Nelson, T en_US
dc.contributor.author Bergeest, R en_US
dc.contributor.author Ramm, G en_US
dc.contributor.author Carranza, R en_US
dc.contributor.author Corney, AC en_US
dc.contributor.author Gibbes, M en_US
dc.contributor.author Kyriazis, G en_US
dc.contributor.author Laiz, HM en_US
dc.contributor.author Liu, LX en_US
dc.contributor.author Lu, Z en_US
dc.contributor.author Pogliano, U en_US
dc.contributor.author Rydler, KE en_US
dc.contributor.author Shapiro, E en_US
dc.contributor.author So, E en_US
dc.contributor.author Temba, M en_US
dc.contributor.author Wright, P en_US
dc.date.accessioned 2007-02-06T13:05:19Z en_US
dc.date.accessioned 2007-06-07T10:05:30Z
dc.date.available 2007-02-06T13:05:19Z en_US
dc.date.available 2007-06-07T10:05:30Z
dc.date.issued 2001-04 en_US
dc.identifier.citation Oldham, KH, et al. 2001. International comparison of 50/60 Hz power (1996-1999). IEEE Transactions on Instrumentation and Measurement, vol. 50(2), pp 356-360 en_US
dc.identifier.issn 0018-9456 en_US
dc.identifier.uri http://hdl.handle.net/10204/1541 en_US
dc.identifier.uri http://hdl.handle.net/10204/1541
dc.description.abstract An international comparison of 50/60 Hz power is described. The travelling standard was an electronic power transducer that was tested at 120 V, 5 A, 53 Hz, at five power factors (1.0, 0.5, and 0.0). Fifteen National Metrology Institutes (NMIs) from six metrology regions participated in the comparison. en_US
dc.format.extent 221941 bytes en_US
dc.format.mimetype application/pdf en_US
dc.language.iso en en_US
dc.publisher IEEE-Institute of Electrical Electronics Engineers Inc en_US
dc.rights Copyright: 2001 IEEE-Institute of Electrical Electronics Engineers Inc en_US
dc.subject Hz power standards en_US
dc.subject NMI power standards en_US
dc.subject Travelling standards en_US
dc.subject National metrology institutes en_US
dc.subject Electrical engineering en_US
dc.subject Instrumentation en_US
dc.title International comparison of 50/60 Hz power (1996-1999) en_US
dc.type Article en_US
dc.identifier.apacitation Oldham, N., Nelson, T., Bergeest, R., Ramm, G., Carranza, R., Corney, A., ... Wright, P. (2001). International comparison of 50/60 Hz power (1996-1999). http://hdl.handle.net/10204/1541 en_ZA
dc.identifier.chicagocitation Oldham, N, T Nelson, R Bergeest, G Ramm, R Carranza, AC Corney, M Gibbes, et al "International comparison of 50/60 Hz power (1996-1999)." (2001) http://hdl.handle.net/10204/1541 en_ZA
dc.identifier.vancouvercitation Oldham N, Nelson T, Bergeest R, Ramm G, Carranza R, Corney A, et al. International comparison of 50/60 Hz power (1996-1999). 2001; http://hdl.handle.net/10204/1541. en_ZA
dc.identifier.ris TY - Article AU - Oldham, N AU - Nelson, T AU - Bergeest, R AU - Ramm, G AU - Carranza, R AU - Corney, AC AU - Gibbes, M AU - Kyriazis, G AU - Laiz, HM AU - Liu, LX AU - Lu, Z AU - Pogliano, U AU - Rydler, KE AU - Shapiro, E AU - So, E AU - Temba, M AU - Wright, P AB - An international comparison of 50/60 Hz power is described. The travelling standard was an electronic power transducer that was tested at 120 V, 5 A, 53 Hz, at five power factors (1.0, 0.5, and 0.0). Fifteen National Metrology Institutes (NMIs) from six metrology regions participated in the comparison. DA - 2001-04 DB - ResearchSpace DP - CSIR KW - Hz power standards KW - NMI power standards KW - Travelling standards KW - National metrology institutes KW - Electrical engineering KW - Instrumentation LK - https://researchspace.csir.co.za PY - 2001 SM - 0018-9456 T1 - International comparison of 50/60 Hz power (1996-1999) TI - International comparison of 50/60 Hz power (1996-1999) UR - http://hdl.handle.net/10204/1541 ER - en_ZA


Files in this item

This item appears in the following Collection(s)

Show simple item record