dc.description.abstract |
A chromaticity comparison took place in order to fulfil the requirements of the mutual recognition agreement (MRA) between the South African National Metrology Laboratory (CSIR/NML) and the Taiwanese National Measurement Laboratory (ITRI/CMS). The absolute spectral reflectance of each standard of a set of 12 BCRL Series II standards was measured on spectrophotometers for 0 degrees/d geometry by a comparison method with a white reference standard. The CIE chromaticity values were calculated under the conditions of Illuminants A, C and D65 for a 2 degrees observer. Good agreement was found in general between the results of CSIR/NML and ITRI/CMS within the respective uncertainty calculations. |
en_US |
dc.format.extent |
109646 bytes |
en_US |
dc.format.mimetype |
application/pdf |
en_US |
dc.language.iso |
en |
en_US |
dc.publisher |
Elsevier Science BV |
en_US |
dc.rights |
Copyright: 1999 Elsevier Science BV |
en_US |
dc.source |
|
en_US |
dc.subject |
Spectral reflectance |
en_US |
dc.subject |
BCRL series II colour standards |
en_US |
dc.subject |
CIE chromaticity values |
en_US |
dc.subject |
Illuminants |
en_US |
dc.subject |
Analytical chemistry |
en_US |
dc.title |
Comparison of CIE chromaticity values |
en_US |
dc.type |
Article |
en_US |
dc.identifier.apacitation |
Van Tonder, N., Denner, B., & Chang, M. (1999). Comparison of CIE chromaticity values. http://hdl.handle.net/10204/1509 |
en_ZA |
dc.identifier.chicagocitation |
Van Tonder, N, BF Denner, and MS Chang "Comparison of CIE chromaticity values." (1999) http://hdl.handle.net/10204/1509 |
en_ZA |
dc.identifier.vancouvercitation |
Van Tonder N, Denner B, Chang M. Comparison of CIE chromaticity values. 1999; http://hdl.handle.net/10204/1509. |
en_ZA |
dc.identifier.ris |
TY - Article
AU - Van Tonder, N
AU - Denner, BF
AU - Chang, MS
AB - A chromaticity comparison took place in order to fulfil the requirements of the mutual recognition agreement (MRA) between the South African National Metrology Laboratory (CSIR/NML) and the Taiwanese National Measurement Laboratory (ITRI/CMS). The absolute spectral reflectance of each standard of a set of 12 BCRL Series II standards was measured on spectrophotometers for 0 degrees/d geometry by a comparison method with a white reference standard. The CIE chromaticity values were calculated under the conditions of Illuminants A, C and D65 for a 2 degrees observer. Good agreement was found in general between the results of CSIR/NML and ITRI/CMS within the respective uncertainty calculations.
DA - 1999-02-02
DB - ResearchSpace
DP - CSIR
KW - Spectral reflectance
KW - BCRL series II colour standards
KW - CIE chromaticity values
KW - Illuminants
KW - Analytical chemistry
LK - https://researchspace.csir.co.za