dc.contributor.author |
Van Zyl, FJ
|
|
dc.contributor.author |
Belle, BK
|
|
dc.date.accessioned |
2007-11-12T10:09:14Z |
|
dc.date.available |
2007-11-12T10:09:14Z |
|
dc.date.issued |
2000-06 |
|
dc.identifier.citation |
Van Zyl, FJ and Belle, BK. 2000. Quantification of methane behaviour in continuous miner headings using a controlled environment. Safety in Mines Research Advisory Committee, COL 619, June, 2000, pp 1-49 |
en |
dc.identifier.uri |
http://hdl.handle.net/10204/1489
|
|
dc.description.abstract |
The aim of this project was to determine the methane control and dilution ability of the retrofitted hood and half-curtain ventilation systems. The two systems were tested in the full-scale ventilation test gallery at CSIR Miningtek’s Kloppersbos Test Facility. The effect of three variables were investigated during the test series, namely the distance of the force column outlet from the face, the pressure of the water supply to the spray fan system, and the rate of methane release into the test section. The tests were conducted for an identified worst-case scenario under static ventilation conditions. |
en |
dc.language.iso |
en |
en |
dc.subject |
SIMRAC |
en |
dc.subject |
COL 619 |
en |
dc.subject |
Methane controls |
en |
dc.subject |
Half-curtain ventilation systems |
en |
dc.title |
Quantification of methane behaviour in continuous miner headings using a controlled environment. |
en |
dc.type |
Conference Presentation |
en |
dc.identifier.apacitation |
Van Zyl, F., & Belle, B. (2000). Quantification of methane behaviour in continuous miner headings using a controlled environment. http://hdl.handle.net/10204/1489 |
en_ZA |
dc.identifier.chicagocitation |
Van Zyl, FJ, and BK Belle. "Quantification of methane behaviour in continuous miner headings using a controlled environment." (2000): http://hdl.handle.net/10204/1489 |
en_ZA |
dc.identifier.vancouvercitation |
Van Zyl F, Belle B, Quantification of methane behaviour in continuous miner headings using a controlled environment; 2000. http://hdl.handle.net/10204/1489 . |
en_ZA |
dc.identifier.ris |
TY - Conference Presentation
AU - Van Zyl, FJ
AU - Belle, BK
AB - The aim of this project was to determine the methane control and dilution ability of the retrofitted hood and half-curtain ventilation systems. The two systems were tested in the full-scale ventilation test gallery at CSIR Miningtek’s Kloppersbos Test Facility. The effect of three variables were investigated during the test series, namely the distance of the force column outlet from the face, the pressure of the water supply to the spray fan system, and the rate of methane release into the test section. The tests were conducted for an identified worst-case scenario under static ventilation conditions.
DA - 2000-06
DB - ResearchSpace
DP - CSIR
KW - SIMRAC
KW - COL 619
KW - Methane controls
KW - Half-curtain ventilation systems
LK - https://researchspace.csir.co.za
PY - 2000
T1 - Quantification of methane behaviour in continuous miner headings using a controlled environment
TI - Quantification of methane behaviour in continuous miner headings using a controlled environment
UR - http://hdl.handle.net/10204/1489
ER -
|
en_ZA |