dc.contributor.author |
Phume, L
|
|
dc.contributor.author |
Popoola, API
|
|
dc.contributor.author |
Aigbodion, VS
|
|
dc.contributor.author |
Pityana, Sisa L
|
|
dc.date.accessioned |
2019-02-13T07:56:19Z |
|
dc.date.available |
2019-02-13T07:56:19Z |
|
dc.date.issued |
2018 |
|
dc.identifier.citation |
Phume, L. et al. 2018. In-situ formation, anti-corrosion and hardness values of Ti-6Al-4V biomaterial with niobium via laser deposition. International Journal of Surface Science and Engineering, vol. 12(1): 23-39 |
en_US |
dc.identifier.issn |
1749-785X |
|
dc.identifier.issn |
1749-7868 |
|
dc.identifier.uri |
https://www.inderscienceonline.com/doi/pdf/10.1504/IJSURFSE.2018.090053
|
|
dc.identifier.uri |
DOI 10.1504/IJSURFSE.2018.090053
|
|
dc.identifier.uri |
http://hdl.handle.net/10204/10708
|
|
dc.description |
Copyright: 2018 Inderscience. Due to copyright restrictions, the attached PDF file only contains the abstract of the full text item. For access to the full text item, please consult the publisher's website. The definitive version of the work can be found at https://www.inderscienceonline.com/doi/pdf/10.1504/IJSURFSE.2018.090053 |
en_US |
dc.description.abstract |
Ti-6Al-4V alloy biomaterials have low hardness, wear resistance, high corrosion rate and toxicity as results of release of aluminium and vanadium ions that led to the premature failure of the implant. In order to overcome some of these problem that lead to laser cladding of Ti-6Al-4V alloy with Niobium. Three laser parameters (laser power, beam diameter and laser scan speed) were used to ascertain the proper operating condition for this laser process. RofinNd: YAG laser was used in the laser cladding. The electrochemical study was conducted using Hank’s buffered salt solution an environment similar to the human body. The optimum improvement in corrosion resistance resulted to 81.79% when compared with substrate. It has been established that operating parameter for laser cladding of Nb on Ti6Al4V were obtained at: laser power (1,000 W), beam diameter (1 mm) and scan speed (0.3 m/min). |
en_US |
dc.language.iso |
en |
en_US |
dc.publisher |
Inderscience |
en_US |
dc.relation.ispartofseries |
Worklist;21806 |
|
dc.subject |
Niobium |
en_US |
dc.subject |
Laser parameters |
en_US |
dc.subject |
Ti-6Al-4V alloy |
en_US |
dc.subject |
Microstructure and corrosion |
en_US |
dc.title |
In-situ formation, anti-corrosion and hardness values of Ti-6Al-4V biomaterial with niobium via laser deposition |
en_US |
dc.type |
Article |
en_US |
dc.identifier.apacitation |
Phume, L., Popoola, A., Aigbodion, V., & Pityana, S. L. (2018). In-situ formation, anti-corrosion and hardness values of Ti-6Al-4V biomaterial with niobium via laser deposition. http://hdl.handle.net/10204/10708 |
en_ZA |
dc.identifier.chicagocitation |
Phume, L, API Popoola, VS Aigbodion, and Sisa L Pityana "In-situ formation, anti-corrosion and hardness values of Ti-6Al-4V biomaterial with niobium via laser deposition." (2018) http://hdl.handle.net/10204/10708 |
en_ZA |
dc.identifier.vancouvercitation |
Phume L, Popoola A, Aigbodion V, Pityana SL. In-situ formation, anti-corrosion and hardness values of Ti-6Al-4V biomaterial with niobium via laser deposition. 2018; http://hdl.handle.net/10204/10708. |
en_ZA |
dc.identifier.ris |
TY - Article
AU - Phume, L
AU - Popoola, API
AU - Aigbodion, VS
AU - Pityana, Sisa L
AB - Ti-6Al-4V alloy biomaterials have low hardness, wear resistance, high corrosion rate and toxicity as results of release of aluminium and vanadium ions that led to the premature failure of the implant. In order to overcome some of these problem that lead to laser cladding of Ti-6Al-4V alloy with Niobium. Three laser parameters (laser power, beam diameter and laser scan speed) were used to ascertain the proper operating condition for this laser process. RofinNd: YAG laser was used in the laser cladding. The electrochemical study was conducted using Hank’s buffered salt solution an environment similar to the human body. The optimum improvement in corrosion resistance resulted to 81.79% when compared with substrate. It has been established that operating parameter for laser cladding of Nb on Ti6Al4V were obtained at: laser power (1,000 W), beam diameter (1 mm) and scan speed (0.3 m/min).
DA - 2018
DB - ResearchSpace
DP - CSIR
KW - Niobium
KW - Laser parameters
KW - Ti-6Al-4V alloy
KW - Microstructure and corrosion
LK - https://researchspace.csir.co.za
PY - 2018
SM - 1749-785X
SM - 1749-7868
T1 - In-situ formation, anti-corrosion and hardness values of Ti-6Al-4V biomaterial with niobium via laser deposition
TI - In-situ formation, anti-corrosion and hardness values of Ti-6Al-4V biomaterial with niobium via laser deposition
UR - http://hdl.handle.net/10204/10708
ER -
|
en_ZA |